product

Building an IT-based Gas Monitoring System Utilizing Core Gas Detector Technology

FLAMMABLE GAS DETECTOR

Home  >  Products  >  GAS DETECTOR  >  FLAMMABLE GAS DETECTOR

Combustible Gas Detector

차량정보 표
Model No. FLAMMABLE GAS DETECTOR QM-9000D
Category GAS DETECTOR, Combustible Gas Detector

Description

Description
  • TRANSMITTER TYPE (4~20mA), RS-485 Modbus (OPTION)
  • FND LOCAL DIGITAL DISPLAY
  • MODEL :QM-9000D
Features
  • Premium diffusion gas detector for real-time monitoring of combustible gases in locations with potential explosion hazards.
  • Flickering or lightning user selection feature.
  • Gas detector with on-site display and backlit LCD for continuous identification of combustible gas concentration in low-light conditions.
  • High-intensity LED Warning Flash Lamp (H.HH).
  • Gas detector with various functions such as zero and concentration calibration, temperature compensation, and record verification of the final calibration date via magnetic key or computer monitoring system.
  • 4~20mA, Dry contact (1st, 2nd, 3rd), 24V DC, Fault output function (Option).
  • IP66 and Internal pressure explosion-proof certified by IECEx, ATEX, and KGS.
  • Galvanically isolated RS-485 network: a highly robust field-bus network capable of limiting the propagation of external noise, such as lightning, to a localized area.
  • When expanding the detection unit, it automatically connects to the nearest communication line and integrates with the rellated computer monitoring system, allowing for automatic expansion and contraction, resulting in cost savings for installation and maintenance management.
Specification
Model No.
QM-9000D
Measuring gas
FLAMMABLE GAS (H2, CH4, C2H2, C2H4, Freon etc.)
Measuring range
0~100%(LEL)
Application sensor
Catalytic combustion
NDIR (Infrared)
Semiconductor
Measuring signal
Relay Contact(H.HH) or 24V.DC(H.HH) Fault
RS-485 Modbus (OPTION)>
Measuring display
4digit FND Digital & 4LED display (Power, Low, High, Fault)
Warning, flickering, lighting
Response time
Within 15~45 seconds (Depends on sensor type)
Transmission speed
38,400bps
Accuracy
±2% / Full scale or ±3% /Full scale (Depends on sensor type)
Operating temp '/humi
-20°C~+40°C/90% RH (Non-condensing) (Depends on sensor type)
Operating power
21~31V.DC
Consumption electric power
1.92W (Alarm 4.56W)
Cable/Distance
UL2919 1pair (RS-485), supply 24V.DC/Max1,000M
CVVS(Shield) 1.5sq x 3wire (4~20mA)/Max2,500M
Conduit connection cable
3/4(22MM) PF
Mounting type
Wall mounting or 2" Pole mounting
Approval
Ex d IIC T6 (IP66) (KOSHA)
Dimension
126(W) × 208(H) × 126(D)
Weight
1.65 Kgs
DIMENSION(mm)