Model No. TOXIC & OXYGEN GAS DETECTOR QM-9100D
Category GAS DETECTOR

Description

Description
  • TRANSMITTER TYPE (4–20mA), RS-485 MODBUS (OPTION)
  • LCD LOCAL DIGITAL DISPLAY
  • MODEL : QM-9100D
Features

- Premium gas detector for real-time monitoring of toxic gas and oxygen concentration in areas with

potential toxic gas presence.

- Gas detector with on-site display and backlight LCD feature for continuous identification of toxic gas

concentration in low-light conditions.

- High-intensity LED warning flash lamp (H.HH).

- Gas detector with various functions, including zero and concentration calibration, temperature compensation,

and final calibration date verification via magnetic key or computer monitoring system without opening the cover.

- Onboard 420mA output, dry contact output (1st, 2nd, 3rd), optional 24V DC output, and fault detection function.

- Computer system with bidirectional communication function on the controller.

- IP66 and Internal pressure explosion-proof certified by IECEx, ATEX, and KGS.

- Galvanically isolated RS-485 network: a highly robust field-bus network capable of limiting the propagation of

external noise, such as lightning, to a localized area.

- When expanding the detection unit, it connects to the nearest communication line and automatically integrates

with the computer monitoring system, allowing for automatic expansion and contraction, resulting in cost savings

for installation and maintenance management.

Specification

Model No.

QM-9100D (T)

Measuring gas

TOXIC GAS (CO, CL2, NH3, H2S,

NO, NO2, CO2 etc.)

O2 (Oxygen)

Measuring range

0~PPM Toxic gas

(Refer to the range for toxic gases)

0~25%(Vol)-Oxygen

Application sensor

 Electro-chemical Semiconductor NDIR(Infrared)  

Measuring signal

4~20mA (Transmitter)

Relay Contact (H.HH) or 24V.DC (H.HH), Fault

RS-485 Modbus/ Hart Protocol(OPTION)

Measuring display

LCD Digital display
Warning, flickering, lighting

Response time

Within 15~45 seconds

(Depends on sensor type)

Transmission speed

38,400bps

Accuracy

±2%/Full scale

Operating temp´/humi´

-20℃~+40℃/90% RH(Non-condensing)

Operating power

21~31V.DC, 125mA

Consumption

electric power

2.4W (Alarm 4.0W)

Cable/Distance

UL-2919 1pair(RS-485 통신),supply 24V.DC-Max 1,000M
CVVS(Shield) 1.5sq × 3wire(4~20mA.DC)-Max 2,500M

Conduit connection cable

3/4(22MM)-14NPT

Mounting type

Wall mounting or 2″ Pole mounting

Approval

Ex db IIC T6 Gb / Ex tb IIIC T85°C Db (KCs)
II 2G Ex db IIC T6 Gb/II 2D Ex tb IIIC T85°C Db (ATEX)
Ex db IIC T6 Gb/Ex tb IIIC T85°C C Db (IECEx)

Dimension

143(W) × 175(H) × 116(D)

- Excluding splash guard

Weight

1.42Kgs
DIMENSION(mm)